Sale!

WhisperKOOL Platinum Split 4000 Ducted Wine Cellar Cooling System

Original price was: $299.99.Current price is: $75.00.

SKU: IVJRV521102 Category:

Description

WhisperKOOL Platinum Split 4000 Ducted Wine Cellar Cooling System

The WhisperKOOL Platinum Split 4000 Ducted Wine Cellar Cooling System is engineered to provide reliable, quiet, and efficient climate control for wine cellars up to approximately 1,000 cubic feet when properly insulated and sealed with a vapor barrier. Its fully ducted split‑system design allows the evaporator and condenser to be installed separately—keeping noise and heat outside the cellar while delivering conditioned air into the space through flexible ducting.

This system’s high‑quality engineering ensures consistent temperature control, preserving wine at optimal storage conditions and helping protect your collection over time. The ducted setup also maintains a clean cellar aesthetic, with air quietly delivered through vents rather than exposed equipment.

Equipped with advanced control features, including a digital thermostat and an optional liquid‑temperature bottle probe, the Platinum Split 4000 offers precise monitoring and adjustment of cellar conditions. Professional HVAC‑R installation is recommended to ensure peak performance and maintain the manufacturer’s warranty.

Whether you’re building a custom wine room or upgrading an existing cellar, this cooling system delivers dependable performance and flexible installation options to meet your specific needs.

Is the WhisperKOOL Platinum Split 4000 the Right Cooling System for Your Wine Cellar?

The WhisperKOOL Platinum Split 4000 is a professional-grade ducted split wine cellar cooling system rated for cellars up to approximately1,000 cubic feet when properly insulated and vapor sealed. With 3120 BTU/h cooling capacity and remote condenser placement, it provides quiet, flexible cooling for permanent residential wine cellars.

Professional HVAC installation is required.

Is the Platinum Split 4000 Right for Your Cellar?

This system is appropriate if:

  • Your cellar is ≤ 1,000 cubic feet
  • Walls are insulated to minimum R-19
  • Ceiling is insulated to minimum R-30
  • A continuous 6-mil vapor barrier is installed
  • The door is sealed and insulated
  • You have space for remote condenser placement
  • You can use a licensed HVAC installer

This system is not appropriate if:

  • The room is unfinished or uninsulated
  • The vapor barrier is missing
  • The cellar exceeds 1,000 cubic feet
  • You want a plug-and-play DIY system
  • Proper drainage cannot be installed

Improper installation or inadequate insulation will cause continuous runtime and may shorten compressor life.

Cooling Capacity & Performance

Rated Cellar Size

  • Approximately 1,000 cubic feet

Cooling Capacity

  • 3120 BTU/h
    (Tested with 85°F air entering condenser coil)

Temperature Performance

  • Designed to maintain 55°F cellar temperature
    Supports condenser air intake temperatures up to 110°F
  • Actual performance depends entirely on heat load, insulation quality, glass exposure, and ambient conditions. A professional heat load calculation is recommended before purchase.

How the Split System Works

The system separates cooling into two components:

Model 4000 Evaporator (Fan Coil Unit)

  • Installed inside or near the cellar
  • Circulates cooled air through ducting
  • Includes 50-ft digital thermostat cable
  • Includes 50-ft liquid temperature bottle probe

The bottle probe measures wine temperature rather than just air temperature for more accurate control.

4000 Air-Cooled Condensing Unit

  • Installed remotely (garage, mechanical room, or approved exterior location)
  • Removes heat from the system
  • Keeps cellar noise minimal

Because the compressor is not located inside the cellar, the system operates significantly quieter than most self-contained units.

Installation Requirements

This is not a self-contained unit. HVAC installation is mandatory.

Electrical Requirements

  • 115V
  • 15-amp dedicated circuit (evaporator and condenser)

Line Set Requirements

  • Liquid line: 1/4″
  • Suction line:
    • 1/2″ for runs under 50 ft.
    • 5/8″ for runs over 50 ft.

Maximum Distance Limits

  • Condenser: up to 100 line feet from evaporator
  • Evaporator: up to 25 duct feet from cellar

Exceeding manufacturer distance limits reduces efficiency and may void warranty.

Ducting Specifications

  • 8″ supply duct
  • 10″ return duct
  • Duct plenum configuration required

Incorrect duct sizing increases static pressure and reduces cooling performance.

Drain Requirements

  • 1/2″ ID clear plastic tubing (not included)
  • Proper slope required
  • Drain line must not trap water

Improper drainage can cause moisture buildup and system damage.

Technical Specifications

Specification Detail
Maximum Cellar Size ~1,000 cu. ft.
Cooling Capacity 3120 BTU/h
Condenser Intake Rating 85°F (tested), supports up to 110°F
Horsepower 1/3 HP
Refrigerant R-134a
Voltage 115V
Dedicated Circuit 15 amp
Evaporator Running Amps 1 amp
Compressor LRA 43
Compressor RLA 8
Evaporator Dimensions 20”L x 20.5”W x 15.5”H
Condenser Dimensions 16.08”L x 16.23”W x 12.61”H
Weight 60 lbs each
Line Set 1/4” liquid; 1/2” or 5/8” suction
Max Line Length 100 ft
Max Duct Length 25 ft
Duct Size 8” supply / 10” return
Drain Line 1/2” ID tubing
Warranty Two-year limited warranty (parts & labor)

Manuals for WhisperKOOL Platinum Split 4000:

  • Owner’s Manual for WhisperKOOL Platinum Split 4000 Ducted Cooling System
  • Technician’s Manual for WhisperKOOL Platinum Split 4000 Ducted Cooling System
  • Product Features & Specifications
  • Warranty Information

When to Choose This System

Choose the Platinum Split 4000 if:

  • You want minimal noise inside the cellar
  • You have a mechanical room or remote condenser location
  • You are building a permanent insulated cellar
  • You need ducted airflow flexibility
  • Your cellar heat load fits within 3120 BTU/h

When to Consider a Larger System

You may need a higher-capacity model if:

  • The cellar exceeds 1,000 cubic feet
  • You have significant glass exposure
  • The room shares exterior walls
  • Ambient temperatures are extreme
  • Insulation levels are below recommended minimums

Undersizing can lead to continuous runtime and premature compressor wear.

Important Sizing Notice

Each wine cellar is unique. Glass, lighting, exterior exposure, and door construction all affect heat load.

A professional heat load calculation should always be performed before selecting a cooling unit.

Final Decision Summary

The WhisperKOOL Platinum Split 4000 is a professional-grade, ducted split cooling system engineered for insulated wine cellars up to 1,000 cubic feet. It delivers quiet performance, remote condenser flexibility, and stable 55°F storage when properly installed and sized.

If you are unsure about sizing, insulation compliance, or installation requirements, consult a cooling specialist before purchase.